Direct ELISA


Coating antigen to microplate  

 Provided by: ABCAM (ABCAM-protocols)
1. Dilute the antigen to a final concentration of 20 μg/ml in PBS or other carbonate buffer. Coat the wells of a PVC microtiter plate with the antigen by pipeting 50 μl of the antigen dilution in the top wells of the plate. Dilute down the plate as required.
2. Cover the plate with an adhesive plastic and incubate for 2 h at room temperature, or 4°C overnight. The coating incubation time may require some optimisation.
3. Remove the coating solution and wash the plate twice by filling the wells with 200 μl PBS. The solutions or washes are removed by flicking the plate over a sink. The remaining drops are removed by patting the plate on a paper towel.


Blocking

1. Block the remaining protein-binding sites in the coated wells by adding 200 μl blocking buffer, 5% non fat dry milk/PBS, per well. Alternative blocking reagents include BlockACE or BSA.
2. Cover the plate with an adhesive plastic and incubate for at least 2 h at room temperature or, if more convenient, overnight at 4°C.
3. Wash the plate twice with PBS.


Incubation with the antibody
1. Add 100 μl of the antibody, diluted at the optimal concentration (according to the manufacturer’s instructions) in blocking buffer immediately before use.
2. Cover the plate with an adhesive plastic and incubate for 2 h at room temperature. This incubation time may require optimisation. Although 2 hours is usually enough to obtain a strong signal, if a weak signal is obtained, stronger staining will often observed when incubated overnight at 4°C.
3. Wash the plate four times with PBS.


Detection
1. Dispense 100 μl (or 50 μl) of the substrate solution per well with a multichannel pipet or a multipipet.
2. After sufficient color development (if it is necessary) add 100 μl of stop solution to the wells.
3. Read the absorbance (optical density) of each well with a plate reader.
Note: some enzyme substrates are considered hazardous (potential carcinogens), therefore always handle with care and wear gloves.


Analysis of data

Prepare a standard curve from the data produced from the serial dilutions with concentration on the x axis (log scale) vs absorbance on the Y axis (linear). Interpolate the concentration of the sample from this standard curve.


Buffers and reagents:

Bicarbonate/carbonate coating buffer (100 mM)

Antigen or antibody should be diluted in coating buffer to immobilize them to the wells:
3.03 g Na2CO3
6.0 g NaHCO3
1000 ml distilled water
pH 9.6

PBS:
1.16 g Na2HPO4,
0.1 g KCl
0.1 g K3PO4,
4.0 g NaCl (500 ml distilled water) pH 7.4.

Blocking solution:
Commonly used blocking agents are 1% BSA , serum, non-fat dry milk, casein, gelatin in PBS.

Wash solution:
Usually PBS or Tris-buffered saline (pH 7.4) with detergent such as 0.05% (v/v) Tween20 (TBST).

Antibody dilution buffer:
Primary and secondary antibody should be diluted in 1x blocking solution to reduce non specific binding.